AM-07-54 Improving Crude Unit Overhead System Reliability by Integrating Corrosion Transmitters into a Distributed Control System
David Delve, Honeywell International, Houston, TX
Format:
Electronic (digital download/no shipping)
Associate Member, International Member, Petrochemical Member, Refining Member - $0.00
NonMember - $25.00
Description:
This paper reviews probe technology and a new implementation of on-line, real-time electrochemical corrosion monitoring which, coupled with DCS connectivity and an advanced application approach, enables a new perspective on optimization of refinery crude unit operations-the-integrity optimization window.
Product Details:
Product ID: | AM-07-54 |
---|---|
Publication Year: | 2007 |